Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Shell Technique with a Xenogeneic Cortical Bone Lamina and Particulate Bone Graft for Horizontal Ridge Augmentation: A Case Series
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 43 , Issue 4
July/August 2023

Pages 435–441


Shell Technique with a Xenogeneic Cortical Bone Lamina and Particulate Bone Graft for Horizontal Ridge Augmentation: A Case Series

Gabriele Villa, DDS/Andrea Rizzacasa, DDS/Luis Bessa, DDS/Paolo Spina, MD/Shayan Barootchi, DMD, MS/Lorenzo Tavelli, DDS, MS, PhD/Hom-Lay Wang, DDS, MS, PhD


DOI: 10.11607/prd.5671

The aim of this prospective case series was to evaluate the efficacy and safety of a xenogeneic cortical bone lamina utilized as a “shell” on the buccal aspect of narrow alveolar ridges for horizontal bone augmentation. Fifteen patients requiring multiple implant restorations at sites with moderate to severe horizontal bone deficiency were consecutively enrolled. Horizontal bone augmentation was performed using a xenogeneic cortical bone lamina (XCBL), which was fixed on the buccal aspect of the ridge using titanium screws, and a mixture of particulate autogenous bone graft and porcine hydroxyapatite. CBCT scans were taken at baseline and 6 months after bone augmentation. The healing was uneventful, with no intra- or postoperative complications. Twenty-seven implants were placed in the augmented sites. The calculated average horizontal bone gain from CBCT scans was 4.79 ± 1.64 mm, 5.59 ± 1.51 mm, and 5.79 ± 2.53 mm at 1-, 3-, and 5-mm reference points apical to the buccal bone crest, respectively. The present case series demonstrated that the shell technique with the XCBL and particulate bone graft can be an effective approach for horizontal bone augmentation prior to implant placement.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help